EExe Breather-drain plugs
Raxton EExe Drain Plugs effectively drain any moisture build-up present within the enclosure whilst allowing air in the enclosure to breathe with the surrounding atmosphere minimising moisture build up within the enclosure.
Fastened by means of an allen key the Drain Plug should be fitted at the lowest point of the enclosure.
The Drain Plug can be fitted:
a) into a chamfered plain hole using drainage washer and locknut or castellated locknut on the inside of the enclosure.
b) directly into a threaded hole provided that, if the thread protrudes, the drainage hole is visible.
The Drain Plug can be supplied with either a serrated washer and locknut allowing the condensation to drain whilst ensuring the Plug is shakeproof or with a castellated locknut.
The Drain Plug is fitted with an ‘O’ ring as standard ensuring that the IP integrity of the installation is maintained.
Raxton Drain Plugs are marked with the appropriate approval number and size.
Tested to IP66.
Quality
SIRA (0518) 02 ATEX M207
BVQI EN ISO 9001: 2000
Thread specification
Isometric (ISO) to BS3643:1981 or ISO 965 Pts 1 & 3
Imperial (ET) to BS31:1940 (1979)
National Pipe Thread (NPT) to ANSI/ASME:1983
British Standard Pipe (BSP) to BS21:1985
Pg to DIN 40430:1971
Materials
Brass: BS2874: 1985 CZ121
Nylon: 30% Glass filled Nylon 66
Stainless Steel: BS970 PT3 316 S11
Approvals
SIRA 00ATEX3074U
GOST POCC GB.M Л14.B00104
Plating
Raxton Metallic Drain Plugs are available in a variety of finishes including Nickel, Electro Zinc, Zinc Passivated, Chromatised, Electroless Nickel and Anodised.
Thread identification
A Selection Table is available as a downloadable PDF document (82 KB) and identifies the standard thread variations produced and is designed to assist the user in the selection process. Click here to download.
Part numbering system
The Raxton part numbering system document is available as a 100 KB PDF document.
Click here to download.
Temperature
The item is classified as a component and is therefore not given a temperature rating.
'O' ring -50°c to 100°c.
Nylon products -20°c to 65°c.